C - 12
MP-59 FREQUENCY OVER FLOW COUNTER
The Frequency Over Flow Counter (MP-59) is a counter that increments each time the frequency
input to the MLP–Drive causes an overflow. To reset the counter to “0”, press the Clear key.
CP-60 OPEN LOOP
If CP-60 is set to "1", then the J6 Pin 12 input acts as the Scroll Down input. If CP-60 is set to
"2", then this input is the Open/Closed Loop input.
CP-61 DIRECT ENABLE
In the Direct mode of operation, the drive output from the MLP–Drive that is connected to the
motor drive can be set directly. Direct mode is an open-loop mode of operation. Use Direct
Enable (CP-61) to either enable or disable the Direct mode.
Enter "1" to enable the Direct Mode.
Enter “0” to disable the Direct Mode.
Enabled
Code
CP-62 INVERSE SCALING
Use Inverse Scaling (CP-61) to select either the Standard or the Inverse setpoint scaling format.
Enter “2” for Inverse Scaling.
Enter "1" for Standard Scaling.
Inverse Scaling
Code