3 - 32
Jog
Jog increases the RPMs at the acceleration rate that you specified in Acceleration Time
(CP-16) until the Jog Setpoint (CP-05) is achieved. When Jog is terminated, there is no
Deceleration Time (CP-17); the drive comes to an immediate stop. The factory default
Control Parameter for Jog is found in Table 3-25. To modify this default parameter,
refer to Table 3-26. If you are uncertain how to enter a Control Parameter, review the
Operations: Keypad
section, page 3-3.
Table 3-25 Default Jog Control Parameters
CP Parameter Name Parameter Value
CP-05 Jog Setpoint 50
Table 3-26 Entering Jog Control Parameters
CP Parameter Name Parameter Value
CP-05 Jog Setpoint
Enter the RPM at which you want your
system to operate when it is in Jog.
For information on the Jog Logic Input, refer to
Logic Control: Logic Inputs, Jog,
page 3-36.