Contrex CX-1200 Bedienungsanleitung Seite 52

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 55
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 51
Page 50
Jog Reverse has sixth (the least) operating priority. Use Jog Reverse to “Jog” the drive Forward at the rate
indicated in Jog SP (CP-240). The acceleration and deceleration ramps are dictated by Acl Tm Jog (CP-241),
Dcl Tm Jog (CP-243) and Jog SP (CP-240). After the Jog Reverse input is deactivated and the ramped
reference has reached “0”, the CX-1200 automatically reverts to the R-Stop operating state.
To activate Jog Reverse:
Activate Low (closed to common), Level Sensitive, Not-Latched
Use momentary contact - needs to be maintained to remain active
Jog Forward
Jog Reverse
Common
F-Stop
R-Stop
H-Stop
Run
Common
Jog Fwd
Close Maintained
6
7
8
1
2
4
5
3
J6
H-Stop
Run
R-Stop
Jog Rvs
F-Stop
Figure 2-51 Jog Reverse Input
Seitenansicht 51
1 2 ... 47 48 49 50 51 52 53 54 55

Kommentare zu diesen Handbüchern

Keine Kommentare