Page 20
Figure 28 Sync Disable
Sync Disable
8
7
J7
Com
D
I_13
Figure 27 Position Reset
Position Reset
6
8
J7
D
I_12
Com
Figure 29 Phase Advance
Phase Advance
8
9
J7
Com
D
I-14
Sync Disable
(J7 pins 7, 8)
Digital Input 13
Sync Disable is a maintained input. When it is closed, it
disables sync corrections.
Position Reset
(J7 pins 6, 8)
Digital Input 12
Position Reset is a momentary input. When it is closed, the
CX-1200 resets the Lead and Follower position information to
zero.
Phase Advance
(J7 pins 9, 8)
Digital Input 14
Phase Advance is a maintained input. When it is closed it
increments the CP selected by "Remote Scroll" (CP-400) at the
rate set by "Rmt Scroll Rate" (CP-401). As a maintained input,
Phase Advance is only active when the operator device is
closed.