Output B activates peripheral equipment in response to the Output B parameters. This
peripheral equipment can be set up to add material (e.g., adhesive or paint) during
specific segments of the Follower profile.
Output B Segment (CP-93)
Use the Output B Segment (CP-93) parameter to determine what
segment of the Follower profile will activate Output B.
Enter “1” in CP-93 to activate Output B during the constant pitch plateau
segment of the Follower profile.
Enter “2” in CP-93 to activate Output B during the constant pitch plateau
and Accel/Decel segments of the Follower profile.
Enter “3” in CP-93 to activate Output B during the dwell segment of the
Follower profile.
The diagram below illustrates the segments of the Follower profile :
Constant
Pitch
Plateau
Follower Profile
Accel/Decel
Accel/Decel
Dwell
1
2
3
Output B Direction (CP-94)
Use the Output B Direction (CP-94) parameter to specify the direction in
which Output B will operate.
Enter “1” in CP-94 to activate Output B during the forward direction.
Enter “2” in CP-94 to activate Output B during the reverse direction.
Enter “3” in CP-94 to activate Output B during the forward and reverse
directions.
Output B Polarity (CP-95)
Use the Output B Polarity (CP-95) parameter to specify the voltage
polarity at which Output B will operate.
Enter “0” in CP-95 to activate Output B as Active Low Voltage Level.
Enter “1” in CP-95 to activate Output B as Active High Voltage Level.